AD Dry Air Generator

  • Widely used in transformer installation, maintenance, manufacturing, etc fields
  • Compact design, more convenient for clients to carry machines to different sites;
  • Components cooperate with internationally reputed brands;
  • Automatic control system, equipped with comprehensive protection mechanism;
  • 13 Years of purifier manufacturing experience;
  • Customizable;
  • 2 years warranty, 7*24 hours technical support and after services.

For product pricing, customization, or other inquiries:

Description

| Applications

  • The dry air generator is suitable for providing low dew point dry air during the installation or maintenance of power equipment such as transformers and reactors.
  • The dry air provided by it can ensure that the internal insulation materials of power equipment are not affected by moisture, and workers will not suffocate due to lack of oxygen while working inside the equipment.
  • Compared to using nitrogen, dry air is safer, more reliable, more economical, and more convenient. When using a dry air generator for equipment maintenance, it is not affected by changes in external climate conditions; Especially for overnight operations, all you need to do is seal the flanges and fill them with dry air to 0.02MPa~0.03MPa.
  • The lower the dew point of the air, the less water content in the air, and the drier the gas equipment.
  • When the atmospheric dew point is 20 ℃, the water content in the air is 17.8g/M³;
  • When the atmospheric dew point is -70 ℃, the water content in the air is 0.005g/M³.

| Features

  • Modular design: AD dry air generator adopts a modular design, integrating internationally leading air drying technologies such as compression, freezing, and adsorption. Its effect is good and easy to use and maintain. By using large area Duplex 3D Flash Vaporization Technology, it quickly evaporates liquid water as well as degasses.
  • Unique “one-click control” technology: AD dry air generator adopts a PLC intelligent controller, which can start or stop the equipment by simply pressing the “Start/Stop” button. The equipment operates fully automatically to minimize manual operation errors. Equipping comprehensive machine protection systems, such as power protection, pressure protection, oil liquid level observing system, etc. Make sure the machine works normally.
  • Low dew point of finished gas: The core indicator for measuring a dry air generator is the dew point of the gas supply. The lower the dew point, the drier the air. Low dew point dry air will adsorb moisture inside the transformer to improve insulation performance. The AD series of dry air and compressed drying, freeze-drying, and adsorption drying are integrated and adopt a multi-level filtration system. Regardless of the moisture content in the air, the dew point of the finished gas will rapidly decrease to below -70 ℃.
  • Efficient filtration system: Adopting the “gradually dense” filtration technology, the maximum filtration accuracy is 0.01 µ m, and the solid particle retention rate is as high as 99.99%. The filtration accuracy of the primary filter is 3 µ m, the filtration accuracy of the secondary filter is 1 µ m, and the filtration accuracy of the tertiary filter is 0.01 µ m.
  • Heat-free regeneration of adsorbent: The adsorbent of WEINENG AD dry air generator adopts a fully automatic regeneration method without thermal pressure difference, which eliminates the need for manual baking of the adsorbent.
  • Low regeneration gas consumption: Using Weineng patented drying technology, the regeneration gas consumption is less than 5%. The traditional regeneration method consumes more than 14% of regeneration gas, which is more environmentally friendly and energy-saving.
  • Fully automatic drainage system: The water intercepted by the compression system, refrigeration system, and filtration system will be discharged into the water collection tank through an automatic drainage device, without the need for manual drainage.
  • A comprehensive protection system: The Weineng AD dry air generator has protection functions such as power section phase mismatch, high voltage, low voltage, motor overload, high pressure, and low pressure.
  • Equipped with a dust removal gun: The Weineng AD dry air generator is equipped with a dust removal gun for easy cleaning of equipment during field operations.

| Functions

  • Removing moisture from the air.
  • Removing particulate matter from the air.
  • During overnight operation of transformers, replace nitrogen gas drying or hot oil circulation drying.
  • Provide dry air during transformer installation and maintenance to ensure dryness inside the transformer.

| Technical Parameter

  • Gas supply volume ≥ 200m³/h
  • Gas supply dew point ≤ -70 ℃
  • Working pressure 0.6~0.8Mpa
  • Air supply pressure 0.02-0.8Mpa (adjustable)
  • Filtering accuracy 0.01 µm
  • Working environment indoor, temperature below 40 ℃, no condensation
  • Power supply three-phase three-wire 380V/50HZ
  • Power 25KW
  • Overall dimensions: Depends on machine capacity

| Flow Chart